Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose
Top Cited Papers
- 8 April 2008
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 18 (9), 1809-1817
- https://doi.org/10.1007/s00330-008-0966-1
Abstract
The purpose of this study was to investigate the effect of low kilovoltage dual-source computed tomography coronary angiography (CTCA) on qualitative and quantitative image quality parameters and radiation dose. Dual-source CTCA with retrospective ECG gating was performed in 80 consecutive patients of normal weight. Forty were examined with a standard protocol (120 kV/330mAs), 20 were examined at 100 kV/330mAs, and 20 at 100 kV/220mAs. Two blinded observers independently assessed image quality of each coronary segment and measured the image parameters noise, attenuation, and contrast-to-noise ratio (CNR). The effective radiation dose was calculated using CT dose volume index and the dose-length product. Diagnostic image quality was obtained in 99% of all coronary segments (1,127/1,140) without significant differences among the protocols. Image noise, attenuation, and CNR were significantly higher for 100 kV/330mAs (26 ± 3 HU, 549 ± 62 HU, 25.5 ± 3.2; each P < 0.01) and 100 kV/220mAs (27 ± 2 HU, 560 ± 43 HU, 25.0 ± 2.2; each P < 0.01) when compared to the 120-kV protocol (21 ± 2 HU, 317 ± 28 HU, 20.6 ± 1.7). There was no significant difference between the two 100-kV protocols. Estimated effective radiation dose of the 120-kV protocol (8.9 ± 1.2 mSv) was significantly higher than the 100 kV/330mAs (6.7 ± 0.8 mSv, P < 0.01) or 100 kV/220mAs (4.4 ± 0.6 mSv, P < 0.001) protocols. Dual-source CTCA with 100 kV is feasible in patients of normal weight, results in a diagnostic image quality with a higher CNR, and at the same time significantly reduces the radiation dose.Keywords
This publication has 32 references indexed in Scilit:
- Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16-slice and 64-slice scanner data with conventional coronary angiographyHeart, 2007
- Image Quality and Reconstruction Intervals of Dual-Source CT Coronary AngiographyInvestigative Radiology, 2007
- Assessment of Coronary Artery Disease by Cardiac Computed TomographyCirculation, 2006
- Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate controlEuropean Radiology, 2006
- Coronary CT Angiography with 64-MDCT: Assessment of Vessel VisibilityAmerican Journal of Roentgenology, 2006
- MDCT of the Coronary Arteries: Feasibility of Low-Dose CT with ECG-Pulsed Tube Current Modulation to Reduce Radiation DoseAmerican Journal of Roentgenology, 2006
- Image Quality, Motion Artifacts, and Reconstruction Timing of 64-Slice Coronary Computed Tomography Angiography With 0.33-Second Rotation SpeedInvestigative Radiology, 2006
- Image Quality of Noninvasive Coronary Angiography Using Multislice Spiral Computed Tomography and Electron-beam Computed TomographyInvestigative Radiology, 2004
- A Quantitative Theory of the Hounsfield Unit and Its Application to Dual Energy ScanningJournal of Computer Assisted Tomography, 1977
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975