A new set of fluence-to-absorbed dose and fluence-to-effective dose conversion coefficients have been calculated for neutrons below 20 MeV using a whole-body anatomical model, VIP-Man, developed from the high-resolution transverse colour photographic images of the National Library of Medicine's Visible Human Project®. Organ dose calculations were performed using the Monte Carlo code MCNP for 20 monoenergetic neutron beams between 1×10-9 MeV and 20 MeV under six different irradiation geometries: anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic. The absorbed dose for 24 major organs and effective dose results based on the realistic VIP-Man are presented and compared with those based on the simplified MIRD-based phantoms reported in the literature. Effective doses from VIP-Man are not significantly different from earlier results for neutrons in the energy range studied. There are, however, remarkable deviations in organ doses due to the anatomical differences between the image-based and the earlier mathematical models.Keywords
This publication has 8 references indexed in Scilit:
- VIP-MAN: AN IMAGE-BASED WHOLE-BODY ADULT MALE MODEL CONSTRUCTED FROM COLOR PHOTOGRAPHS OF THE VISIBLE HUMAN PROJECT FOR MULTI-PARTICLE MONTE CARLO CALCULATIONSHealth Physics, 2000
- A Realistic Anthropomorphic Phantom for Calculating Organ Doses Arising from External Photon IrradiationRadiation Protection Dosimetry, 1997
- Realistic computerized human phantomsAdvances in Space Research, 1994
- Conversion Functions of the Dose Equivalent HSL(10) in the ICRU Slab Used For the Calibration of Personal Neutron DosemetersRadiation Protection Dosimetry, 1994
- An Extended Tabulation of Effective Dose Equivalent from Neutrons Incident on a Male Anthropomorphic PhantomHealth Physics, 1993
- Calculated Effective Doses in Anthropoid Phantoms for Broad Neutron Beams with Energies from Thermal to 19 MeVRadiation Protection Dosimetry, 1992
- Effective Dose Equivalent and Organ Doses for Neutrons from Thermal to 14 MeV - (Letter to the Editor)Radiation Protection Dosimetry, 1990
- The Absorbed Dose and Dose Equivalent from Neutrons in the Energy Range 60 to 3000 MeV and Protons in the Energy Range 400 to 3000 MeVNuclear Science and Engineering, 1970