Comparison of cone beam computed tomography imaging with physical measures
Top Cited Papers
- 1 February 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in Dento maxillo facial radiology
- Vol. 37 (2), 80-93
- https://doi.org/10.1259/dmfr/31349994
Abstract
The goal of this study was to determine the accuracy of measuring linear distances between landmarks commonly used in orthodontic analysis on a human skull using two cone beam CT (CBCT) systems. Measurements of length were taken using volumetric data from two CBCT systems and were compared with physical measures using a calliper applied to one human adult skull. Landmarks were identified with chromium steel balls embedded at 32 cranial and 33 mandibular landmarks and the linear measures were taken with a digital calliper. The skull was then scanned with two different CBCT systems: the NewTom QR DVT 9000 (Aperio Inc, Sarasota, FL) and the Hitachi MercuRay (Hitachi Medico Technology, Tokyo, Japan). CT data including the landmark point data were threshold segmented using CyberMed's CB Works software (CB Works 1.0, CyberMed Inc., Seoul, Korea). The resulting segmentations were exported from CB Works as VRML (WRL) files to Amira software (Amira 3.1, Mercury Computer Systems GmbH, Berlin, Germany). The error was small compared with the gold standard of the physical calliper measures for both the NewTom (0.07+/-0.41 mm) and CB MercuRay (0.00+/-0.22 mm) generated data. Absolute error to the gold standard was slightly positive, indicating minor compression relative to the calliper measurement. The error was slightly smaller in the CB MercuRay than in the NewTom, probably related to a broader greyscale range for describing beam attenuation in 12-bit vs 8-bit data. The volumetric data rendered with both CBCT systems provided highly accurate data compared with the gold standard of physical measures directly from the skulls, with less than 1% relative error.Keywords
This publication has 39 references indexed in Scilit:
- Cone beam computed tomographic findings in refractory chronic suppurative osteomyelitis of the mandibleBritish Journal of Oral and Maxillofacial Surgery, 2007
- Three-dimensional cone-beam computed tomography for assessment of mandibular changes after orthognathic surgeryAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- Density conversion factor determined using a cone-beam computed tomography unit NewTom QR-DVT 9000Dento maxillo facial radiology, 2006
- Evaluation of cross-section airway configuration of obstructive sleep apneaOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006
- Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomographyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Osseous abnormalities of the mandibular condyle: diagnostic reliability of cone beam computed tomography compared with helical computed tomography based on an autopsy materialDento maxillo facial radiology, 2006
- Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot studyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006
- State-of-the-art on cone beam CT imaging for preoperative planning of implant placementClinical Oral Investigations, 2006
- Three-dimensional localization of maxillary canines with cone-beam computed tomographyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2005
- Diagnosis goes digitalAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2004