Carotid occlusive disease: effect of complete occlusion of internal carotid artery on intraocular pulse/pressure relation and on ophthalmic arterial pressure.
- 1 November 1981
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 12 (6), 759-765
- https://doi.org/10.1161/01.str.12.6.759
Abstract
The intraocular pressure (IOP), the intraocular pulse to pressure (pulse/pressure) relationship and the ophthalmic arterial pressure were measured in 20 patients with either unilateral or bilateral hemodynamically significant lesions of the internal carotid arteries (ICA) as determined from arteriography. Studies were repeated in 5 of the patients after surgical endarterectomy on the obstructed ICA. In age-matched normal subjects the pulse/pressure relations were symmetrical in pairs of eyes and the ophthalmic arterial systolic pressure was 89.0 .+-. 2.1 mm Hg; this was 66 .+-. 1% of the brachial arterial systolic pressure. In 19 of 20 patients with carotid occlusive disease in this study, the IOP, pulse amplitudes and the pulse/pressure relationships differed in pairs of eyes. The ophthalmic arterial systolic pressure on the sides with 95 to 100% ICA stenosis was 49.9 .+-. 4.05 mm Hg, which was 33 .+-. 3% of the brachial arterial systolic pressure. In the remaining eyes the degree of stenosis of the ipsilateral ICA was 36.5 .+-. 7.9%; the corresponding eyes had an ophthalmic arterial systolic pressure of 70.1 .+-. 5.18 mm Hg, which was 45 .+-. 4% of the branchial arterial systolic pressure. Endarterectomy of the occluded arteries caused a significant increase in the ophthalmic arterial pressure on the ipsilateral side and a smaller increase in the contralateral eye; these changes were associated with a statistically significant increase in the intraocular pulse and improvement in the pulse/pressure relation.This publication has 13 references indexed in Scilit:
- An Evaluation of Currently Available, Noninvasive Tests of Carotid Artery DiseaseOphthalmology, 1980
- A clinical procedure for the measurements of the ocular pulse-pressure relationship and the ophthalmic arterial pressureExperimental Eye Research, 1978
- Pneumatic applanation tonometer studies. IV. Analysis of pulsatile responseExperimental Eye Research, 1975
- Pneumatic applanation tonometer studies. III. Analysis of the floating tip sensorExperimental Eye Research, 1975
- Ophthalmodynamometry Using SuctionArchives of Ophthalmology (1950), 1969
- MANOMETRIC STUDIES OF THE PRESSURE VOLUME RELATIONSHIP IN LIVING AND ENUCLEATED EYES OF INDIVIDUAL HUMAN SUBJECTSBritish Journal of Ophthalmology, 1962
- Ophthalmodynamometry in the Surgical Management of Carotid Arterial DiseaseArchives of Ophthalmology (1950), 1961
- Simultaneous determinations of retinal and carotid artery pressuresNeurology, 1960
- Determination of Retinal Artery Pressures in Diagnosis of Carotid Artery OcclusionNeurology, 1957
- Intra-arterial Pressures in the Neck and BrainJournal of Neurosurgery, 1953