Automated Quantitative Evaluation of Lymph Node Perfusion on Contrast-Enhanced Sonography
- 1 April 2007
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 188 (4), 977-983
- https://doi.org/10.2214/ajr.06.0562
Abstract
OBJECTIVE. The aim of this study was to assess the performance of experimental software (Qontraxt) intended to provide automated quantification of sonographic signal intensity, which is related to the contrast enhancement of lymph node tissue, to differentiate benign from malignant lymph nodes. SUBJECTS AND METHODS. In 31 patients (age range, 24-86 years; mean age ± SD, 53.6 ± 14.4 years) a single lymph node per patient was evaluated on sonography after the administration of sulfur hexafluoride-filled microbubbles. The stored sonographic images were analyzed and processed into chromatic maps that had numeric values related to the amount of contrast. The lymph node regions in which the increase of signal intensity values with respect to baseline were highest (maximum signal intensity value [SImax]) and lowest (minimum signal intensity value [SImin]) were identified, and the corresponding numeric data were stored. Statistical analyses were performed by means of the Student's t test; a p value of less than 0.05 was considered to be statistically significant. RESULTS. Histopathologic analysis revealed metastatic lesions in 12 of the 31 lymph nodes; the remaining 19 were benign (16 reactive lymph nodes, two cases of granulomatous lymphadenitis, and one case of tubercular lymphadenitis). Values obtained from the SImax regions showed no consistent difference between benign and malignant lymph nodes; on the other hand, values from the SImin regions comparing baseline and maximal contrast-enhanced values were significantly different in the two groups (p < 0.001). Confidence for characterization of malignancy was significant using the difference between values from SImax and SImin regions, with the higher disgnostic value from 24 to 31 inclusive: sensitivity, 92% (11/12); specificity, 89% (17/19); positive predictive value, 85% (11/13); and accuracy, 90% (28/31). CONCLUSION. The software being tested proved to be useful in differentiating benign from metastatic lymph nodes on the basis of the quantitative data it provided.Keywords
This publication has 19 references indexed in Scilit:
- Urinary Bladder Cancer: Preoperative Nodal Staging with Ferumoxtran-10–enhanced MR ImagingRadiology, 2004
- High‐sensitivity power Doppler imaging of normal superficial lymph nodesJournal of Clinical Ultrasound, 2004
- Necrosis in Metastatic Neck Nodes: Diagnostic Accuracy of CT, MR Imaging, and USRadiology, 2004
- Evaluation of Neck and Body Metastases to Nodes with Ferumoxtran 10–enhanced MR Imaging: Phase III Safety and Efficacy StudyRadiology, 2003
- Improved characterization of reactive and malignant superficial lymph nodes (LN) using harmonic ultrasound with a second-generation contrast agentJapanese Journal of Clinical Oncology, 2003
- Comparison of Sonography and CT for Differentiating Benign from Malignant Cervical Lymph Nodes in Patients with Squamous Cell Carcinoma of the Head and NeckAmerican Journal of Roentgenology, 2001
- Distribution of Intranodal Vessels in Differentiating Benign from Metastatic Neck NodesClinical Radiology, 2001
- Differentiation of Lymphadenopathy in Different Forms of Carcinoma with Doppler SonographyClinical Radiology, 2000
- Diagnostic Procedures for Detection of Lymph Node Metastases in Cancer of the LarynxORL, 2000
- Distinction between benign and malignant causes of cervical, axillary, and inguinal lymphadenopathy: value of Doppler spectral waveform analysis.American Journal of Roentgenology, 1995