Rotational stability of a single-piece hydrophobic acrylic intraocular lens: New method for high-precision rotation control
- 1 May 2007
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (5), 800-803
- https://doi.org/10.1016/j.jcrs.2007.01.030
Abstract
PURPOSE: To use a new method to examine precisely the rotational stability of a foldable hydrophobic single-piece monofocal acrylic intraocular lens (IOL) and determine whether the design is suitable for a toric lens. SETTING: University Eye Hospital, University Giessen and Marburg, Giessen, Germany. METHODS: The rotational stability of an acrylic IOL (AcrySof SA60AT, Alcon) was evaluated using digital photographs. Two sets of images of the IOL in 17 eyes were taken. The first set was taken immediately postoperatively and the other, 6 months after cataract surgery. The axial position of the eye was determined using 2 characteristic points at the conjunctiva and on the IOL. These points were then connected with a line and an angle determined. Comparing the 2 sets of images yielded an angle Δ that revealed the rotation. RESULTS: The median IOL rotation was 0.7 degree (range 0.1 to 1.8 degrees). Rotation greater than 0 degree and less than 0.5 degree was measured in 4 eyes (24%). Rotation of 0.5 to 1.0 degree was found in 8 eyes (47%). A rotational angle greater than 1.0 degree was found in 5 eyes (29%). Rotation did not exceed 1.8 degrees in any eye. CONCLUSIONS: Using a suitable measuring method that takes into account the cyclorotation of the eye, it was possible to precisely determine IOL rotation using picture pairs taken in chronological sequence. The IOL design examined in the study is recommended as a toric IOL because of its good rotational stability.Keywords
This publication has 11 references indexed in Scilit:
- Rotationsstabilität monofokaler Intraokularlinsen mit C-Haptik versus Z-Haptik nach KataraktchirurgieDer Ophthalmologe, 2005
- Evaluating the eye's rotational stability during standard photographyJournal of Cataract & Refractive Surgery, 2005
- Bifokalfotographie mit dem HRA - eine optimierte Methode zur Beurteilung der Achslage torischer IntraokularlinsenKlinische Monatsblätter für Augenheilkunde, 2004
- Messmethode zur Bestimmung der Rotation und der Dezentrierung von IntraokularlinsenDer Ophthalmologe, 2004
- Early rotational stability of the longer Staar toric intraocular lensJournal of Cataract & Refractive Surgery, 2003
- Toric intraocular lens implantation: 100 consecutive casesJournal of Cataract & Refractive Surgery, 2002
- Torische IntraokularlinsenDer Ophthalmologe, 2001
- Capsular bag shrinkage after implantation of an open-loop silicone lens and a poly(methyl methacrylate) capsule tension ringJournal of Cataract & Refractive Surgery, 1997
- Relative strength of scleral corneal and clear corneal incisions constructed in cadaver eyesJournal of Cataract & Refractive Surgery, 1994
- Decentration associated with asymmetric capsular shrinkage and intraocular lens sizeJournal of Cataract & Refractive Surgery, 1993