Tapered LSO arrays for small animal PET
- 30 November 2010
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (1), 139-153
- https://doi.org/10.1088/0031-9155/56/1/009
Abstract
By using detectors with good depth encoding accuracy (∼2 mm), an animal PET scanner can be built with a small ring diameter and thick crystals to simultaneously obtain high spatial resolution and high sensitivity. However, there will be large wedge-shaped gaps between detector modules in such a scanner if traditional cuboid crystal arrays are used in a polygonal arrangement. The gaps can be minimized by using tapered scintillator arrays enabling the sensitivity of the scanner to be further improved. In this work, tapered lutetium oxyorthosilicate (LSO) arrays with different crystal dimensions and different combinations of inter-crystal reflector and crystal surface treatments were manufactured and their performance was evaluated. Arrays were read out from both ends by position-sensitive avalanche photodiodes (PSAPDs). In the optimal configuration, arrays consisting of 0.5 mm LSO elements could be clearly resolved and a depth of interaction resolution of 2.6 mm was obtained for a 20 mm thick array. For this tapered array, the intrinsic spatial is degraded from 0.67 to 0.75 mm compared to a standard cuboidal array with similar dimensions, while the increase in efficiency is 41%. Tapered scintillator arrays offer the prospect of improvements in sensitivity and sampling for small-bore scanners, without large increases in manufacturing complexity.Keywords
This publication has 34 references indexed in Scilit:
- Simulation study of spatial resolution and sensitivity for the tapered depth of interaction PET detectors for small animal imagingPhysics in Medicine & Biology, 2009
- Experimental characterization and system simulations of depth of interaction PET detectors using 0.5 mm and 0.7 mm LSO arraysPhysics in Medicine & Biology, 2009
- Continuous depth-of-interaction encoding using phosphor-coated scintillatorsPhysics in Medicine & Biology, 2009
- Depth of interaction calibration for PET detectors with dual-ended readout by PSAPDsPhysics in Medicine & Biology, 2008
- Recent developments in PET detector technologyPhysics in Medicine & Biology, 2008
- A Prototype PET Scanner with DOI-Encoding DetectorsJournal of Nuclear Medicine, 2008
- Depth of interaction decoding of a continuous crystal detector modulePhysics in Medicine & Biology, 2007
- In vivomolecular and genomic imaging: new challenges for imaging physicsPhysics in Medicine & Biology, 2004
- Investigation of depth-of-interaction by pulse shape discrimination in multicrystal detectors read out by avalanche photodiodesIEEE Transactions on Nuclear Science, 1999
- Design studies for a PET detector module using a PIN photodiode to measure depth of interactionIEEE Transactions on Nuclear Science, 1994