CT Radiation: Key Concepts for Gentle and Wise Use
- 1 October 2015
- journal article
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 35 (6), 1706-1721
- https://doi.org/10.1148/rg.2015150118
Abstract
Once the appropriateness of CT is established, scanning protocols should be optimized for the specific clinical indication, body habitus, anatomic area, and patient age. Use of computed tomography (CT) in medicine comes with the responsibility of its appropriate (wise) and safe (gentle) application to obtain required diagnostic information with the lowest possible dose of radiation. CT provides useful information that may not be available with other imaging modalities in many clinical situations in children and adults. Inappropriate or excessive use of CT should be avoided, especially if required information can be obtained in an accurate and time-efficient manner with other modalities that require a lower radiation dose, or non–radiation-based imaging modalities such as ultrasonography and magnetic resonance imaging. In addition to appropriate use of CT, the radiology community also must monitor scanning practices and protocols. When appropriate, high-contrast regions and lesions should be scanned with reduced dose, but overly zealous dose reduction should be avoided for assessment of low-contrast lesions. Patients’ cross-sectional body size should be taken into account ...Keywords
This publication has 59 references indexed in Scilit:
- How I Do It: Managing Radiation Dose in CTRadiology, 2014
- Radiation Protection and Dose Monitoring in Medical ImagingJournal of Patient Safety, 2013
- Achieving Routine Submillisievert CT Scanning: Report from the Summit on Management of Radiation Dose in CTRadiology, 2012
- Perspective on radiation risk in CT imagingAbdominal Radiology, 2012
- Strategies for Reducing Radiation Exposure in Multi-Detector Row CTRadiologic Clinics of North America, 2012
- Radiologic and Nuclear Medicine Studies in the United States and Worldwide: Frequency, Radiation Dose, and Comparison with Other Radiation Sources—1950–2007Radiology, 2009
- Risks Associated with Low Doses and Low Dose Rates of Ionizing Radiation: Why Linearity May Be (Almost) the Best We Can DoRadiology, 2009
- The Linear No-Threshold Relationship Is Inconsistent with Radiation Biologic and Experimental DataRadiology, 2009
- Strategies for CT Radiation Dose OptimizationRadiology, 2004
- Cancer risks attributable to low doses of ionizing radiation: Assessing what we really knowProceedings of the National Academy of Sciences, 2003