Creation of two tomographic voxel models of paediatric patients in the first year of life
- 6 August 2002
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 47 (17), 3143-3164
- https://doi.org/10.1088/0031-9155/47/17/307
Abstract
Tomographic computational models, based on regional segmentation of CT or MRI medical images, have increasingly been proposed as replacements for current stylized mathematical models of human anatomy used in radiation dosimetry studies. While much effort has been devoted towards the creation of adult models, few research studies have been initiated to address the need for models supporting paediatric radiology dosimetry. In this study, two tomographic models were created using a combination of automatic and manual segmentation via a program created in-house using IDL version 5.5. The first model is of a normal 6 day female newborn, and consists of a 512 × 512 × 485 data array. The CT slices of this model were obtained every 1 mm, and 66 different anatomic regions were defined. The second model is of a patient developmentally equivalent to a 2 month male, and was saved as a 512 × 512 × 438 data array. This subject had severe tissue oedema within the gut, kidneys, liver and spleen. The model is thus considered representative of a critically ill child, from a patient subpopulation expected to receive a larger than normal number of diagnostic x-ray exams. The voxel volumes for the two models are 0.35 mm3 and 0.30 mm3, respectively, thus making these models the most detailed in existence for paediatric dosimetry applications. Ratios of organ masses for the UF newborn model to those within the reference ORNL/MIRD model range from highs of 1.2 to 1.7 for the oesophagus and small intestine/colon, respectively, to lows of 0.18 to 0.27 for the mandible and humeri, respectively. For the UF 2 month model, ratios of organ masses in the UF model to those in the 8 week GSF BABY model ranged from highs of 3.7 to 5.2 for the clavicles and spleen, respectively, to lows of 0.2 to 0.3 for the adrenals and scapulae, respectively.Keywords
This publication has 16 references indexed in Scilit:
- Voxel effects within digital images of trabecular bone and their consequences on chord-length distribution measurementsPhysics in Medicine & Biology, 2002
- Surface area overestimation within three‐dimensional digital images and its consequence for skeletal dosimetryMedical Physics, 2002
- SKELETAL DOSIMETRY VIA NMR MICROSCOPY: INVESTIGATIONS OF SAMPLE REPRODUCIBILITY AND SIGNAL SOURCEHealth Physics, 2002
- COMPARISON OF ANGULAR FREE-IN-AIR AND TISSUE-EQUIVALENT PHANTOM RESPONSE MEASUREMENTS IN p-MOSFET DOSIMETERSHealth Physics, 2001
- Specific absorbed fractions from the image-based VIP-Man body model and EGS4-VLSI Monte Carlo code: internal electron emittersPhysics in Medicine & Biology, 2001
- Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 versionMedical Physics, 2000
- An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinationsPhysics in Medicine & Biology, 1999
- A Realistic Anthrompomorphic Phantom for Calculating Specific Absorbed Fractions of Energy Deposited from Internal Gamma EmittersRadiation Protection Dosimetry, 1998
- The Characterization of a Commercial Mosfet Dosimeter System for Use in Diagnostic X-RayHealth Physics, 1998
- A Realistic Anthropomorphic Phantom for Calculating Organ Doses Arising from External Photon IrradiationRadiation Protection Dosimetry, 1997