Characterization of a capacitance-coupled contactless conductivity detection system with sidewall electrodes on a low-voltage-driven electrophoresis microchip
- 13 April 2010
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 397 (4), 1583-1593
- https://doi.org/10.1007/s00216-010-3675-y
Abstract
A new type of capacitance-coupled contactless conductivity detection (C4D) system with sidewall electrodes was proposed for integration on a silicon-on-isolator–poly(dimethylsiloxane) (SOI-PDMS) hybrid low-voltage-driven electrophoresis microchip. By a microelectromechanical system process, the sidewall electrodes were fabricated precisely at either side of the separation channel. The area of the capacitor electrodes was the maximum value to improve the detection sensitivity with an enhanced capacitance effect. According to the simulation results, the structural parameters of the sidewall electrodes were determined as 550-μm length, 15-μm width, 80-μm separation distance, and 1-μm isolator thickness. The integrated microdevice with the SOI-PDMS hybrid electrophoresis microchip was very compact and the size was only 15 cm × 15 cm × 10 cm (width × length × height), which permitted miniaturization and portability. The detector performance was evaluated by K+ testing. The detection limit of the conductivity detector was determined to be 10-9 and 10-6 M for K+ in the static and electric-driven modes, respectively. Finally, the C4D was applied to low-voltage-driven electrophoresis on a microchip to carry out real-time measurement of the separation of amino acids. The separations of 10-4 M lysine and phenylalanine in the low-voltage-driven electrophoresis mode were performed with an electric field of 300 V/cm and were completed in less than 15 min with a resolution of 1.3. The separation efficiency was found to be 1.3 × 103 and 2.8 × 103 plates for lysine and phenylalanine, respectively, with a migration time reproducibility of 2.7 and 3.2%. The conductivity detection limit of amino acids achieved was 10-6 M. The proposed method for the construction of a novel C4D integrated on an SOI-PDMS hybrid low-voltage-driven electrophoresis microchip showed the most extensive integration and miniaturization of a microdevice, which is a further crucial step toward the realization of the “lab-on-a-chip” concept.Keywords
This publication has 16 references indexed in Scilit:
- A microsystem of low-voltage-driven electrophoresis on microchip with array electrode pairs for the separation of amino acidsAnalytical and Bioanalytical Chemistry, 2009
- Fabrication and testing investigation of low-voltage integrated electrophoresis chip based on silicon-on-insulator-MEMSJournal of Micro/Nanolithography, MEMS, and MOEMS, 2007
- Application of an external contactless conductivity detector for the analysis of beverages by microchip capillary electrophoresisElectrophoresis, 2005
- Capillary and microchip electrophoresis of basic drugs with contactless conductivity detectionElectrophoresis, 2004
- Contactless conductivity detection of selected organic ions in on‐chip electrophoresisElectrophoresis, 2004
- Detection of Human Immunoglobulin in Microchip and Conventional Capillary Electrophoresis with Contactless Conductivity MeasurementsAnalytical Chemistry, 2004
- Low‐voltage driven control in electrophoresis microchips by traveling electric fieldElectrophoresis, 2003
- Design of low voltage-driven capillary electrophoresis chips using moving electrical fieldsSensors and Actuators B: Chemical, 2001
- Arrayed-electrode design for moving electric field driven capillary electrophoresis chipsSensors and Actuators B: Chemical, 2001
- Miniaturized total chemical analysis systems: A novel concept for chemical sensingSensors and Actuators B: Chemical, 1990