Implant design and intraosseous stability of immediately placed implants: a human cadaver study
- 23 November 2004
- journal article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 16 (2), 202-209
- https://doi.org/10.1111/j.1600-0501.2004.01099.x
Abstract
The objective of this study was to explore effects of implant macrodesign and diameter on initial intraosseous stability and interface mechanical properties of immediately placed implants. Mandibular premolars of four fresh-frozen human cadavers were extracted. Ø 4.1/4.8 mm ITI TE, Ø 4.1 and 4.8 mm solid screw synOcta ITI implants were placed into freshly prepared extraction sockets. Resonance frequency analysis was conducted to quantify primary implant stability quotient (ISQ). Installation torque value (ITV) and removal torque value (RTV) of the implants were measured using a custom-made strain-gauged torque wrench connected to a data acquisition system at a sample rate of 10,000 Hz. The vertical defect depth around the collar of each implant was measured directly by an endodontic spreader. The bone-implant contact was determined in digitalized images of periapical radiographs and expressed as percentage bone contact. The ISQ values of the TE implant was higher than the Ø 4.1 mm implant (P0.05). ITVs and RTVs of TE and Ø 4.8 mm implants were higher than the Ø 4.1 mm implant, although the differences between groups were statistically insignificant (P>0.05). The vertical defect depths around all types of implants were similar. In the radiographic analyses, percentage bone-implant contact of the TE and Ø 4.8 mm implants were comparable at the marginal bone region and both were higher than that of the Ø 4.1 mm ITI implant. Nonparametric correlations between groups revealed a significant correlation between ITV and RTV (r=0.838; P0.05). Immediately placed ITI TE implant leads to initial intraosseous stability and interface mechanical properties comparable with a wide diameter implant.Keywords
This publication has 22 references indexed in Scilit:
- Dynamic fatigue resistance of implant–abutment junction in an internally notched morse‐taper oral implant: influence of abutment designClinical Oral Implants Research, 2004
- Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implantsClinical Oral Implants Research, 2003
- Surgical procedures in partially edentulous patients with ITI implants NoteClinical Oral Implants Research, 2000
- A 5‐year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: peri‐implant outcome.Clinical Oral Implants Research, 1998
- Resonance frequency measurements of implant stability in viva. A cross‐sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla.Clinical Oral Implants Research, 1997
- Quantitative determination of the stability of the implant‐tissue interface using resonance frequency analysisClinical Oral Implants Research, 1996
- The influence of splinting procedures on the periodontal and peri‐implant tissue damping characteristics A longitudinal study with the Periotest® deviceJournal of Clinical Periodontology, 1995
- Tissue integration of non‐submerged implants. l‐year results of a prospective study with 100 ITI hollow‐cylinder and hollow‐screw implants.Clinical Oral Implants Research, 1990
- Observations on the Effect of Movement on Bone Ingrowth into Porous-Surfaced ImplantsClinical Orthopaedics and Related Research, 1986