Multicomponent Assay for Blood Substrates in Human Plasma by Mid-Infrared Spectroscopy and its Evaluation for Clinical Analysis
- 1 January 1994
- journal article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 48 (1), 85-95
- https://doi.org/10.1366/0003702944027598
Abstract
An analytical multicomponent method for the blood substrates total protein, glucose, total cholesterol, triglycerides, and urea in human EDTA plasma by FT-IR spectroscopy is described. The spectra were obtained with the use of the attenuated total reflection technique. Partial least-squares was applied for multivariate calibration over optimized spectral ranges. The mean-square prediction errors for the population of 126 plasma samples of different patients calculated by cross-validation are in the range of clinical acceptance. Within an error variance analysis, the contributions of the reference method and the spectrometric measurement to the average (root mean square) prediction error have been estimated for each substrate, giving evidence of the limitations of the spectrometric method. The problem of the biocompatibility of the plasma has been investigated, and the protein adsorption onto the ATR crystal can be reduced to a constant and tolerable level by appropriate cleaning and rinsing. The potential for further improvement is discussed.Keywords
This publication has 21 references indexed in Scilit:
- Reagentless Near-Infrared Determination of Glucose in Whole Blood Using Multivariate CalibrationApplied Spectroscopy, 1992
- Post-Prandial Blood Glucose Determination by Quantitative Mid-Infrared SpectroscopyApplied Spectroscopy, 1992
- Multivariate determination of blood substrates in human plasma by FT-NIR spectroscopyPublished by SPIE-Intl Soc Optical Eng ,1992
- Quantitative Infrared Spectroscopy Of Glucose In Blood Using Partial Least-Squares AnalysesPublished by SPIE-Intl Soc Optical Eng ,1989
- Comparison Of Multivariate Calibration With PCR And PLS For Glucose Using Infrared Spectra Of Human Whole BloodPublished by SPIE-Intl Soc Optical Eng ,1989
- Multivariate calibration for assays in clinical chemistry using attenuated total reflection infrared spectra of human blood plasmaAnalytical Chemistry, 1989
- Multivariate determination of glucose in whole blood by attenuated total reflection infrared spectroscopyAnalytical Chemistry, 1989
- Determination of Glucose in Blood Using Glucose Oxidase with an Alternative Oxygen AcceptorAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1969
- Die enzymatische Bestimmung von Glucose und Fructose nebeneinanderKlinische Wochenschrift, 1961
- The Use of Pectin and Gelatin in the Processing of Plasma in the Blood BankAmerican Journal of Clinical Pathology, 1946