Signal and noise properties of position-sensitive avalanche photodiodes
- 6 September 2011
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (19), 6327-6336
- https://doi.org/10.1088/0031-9155/56/19/011
Abstract
After many years of development, position-sensitive avalanche photodiodes (PSAPDs) are now being incorporated into a range of scintillation detector systems, including those used in high-resolution small-animal PET and PET/MR scanners. In this work, the signal, noise, signal-to-noise ratio (SNR), flood histogram and timing resolution were measured for lutetium oxyorthosilicate (LSO) scintillator arrays coupled to PSAPDs ranging in size from 10 to 20 mm, and the optimum bias voltage and working temperature were determined. Variations in the SNR performance of PSAPDs with the same dimensions were small, but the SNR decreased significantly with increasing PSAPD size and increasing temperature. Smaller PSAPDs (10 mm and 15 mm in width) produced acceptable flood histograms at 24 °C, and cooling lower than 16 °C produced little improvement. The optimum bias voltage was about 25 V below the break down voltage. The larger 20 mm PSAPDs have lower SNR and require cooling to 0-7 °C for acceptable performance. The optimum bias voltage is also lower (35 V or more below the break down voltage depending on the temperature). Significant changes in the timing resolution were observed as the bias voltage and temperature varied. Higher bias voltages provided better timing resolution. The best timing resolution obtained for individual crystals was 2.8 ns and 3.3 ns for the 10 mm and 15 mm PSAPDs, respectively. The results of this work provide useful guidance for selecting the bias voltage and working temperature for scintillation detectors that incorporate PSAPDs as the photodetector.Keywords
This publication has 24 references indexed in Scilit:
- Tapered LSO arrays for small animal PETPhysics in Medicine & Biology, 2010
- PET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging ApplicationsJournal of Nuclear Medicine, 2010
- A study of the timing properties of position-sensitive avalanche photodiodesPhysics in Medicine & Biology, 2009
- Experimental characterization and system simulations of depth of interaction PET detectors using 0.5 mm and 0.7 mm LSO arraysPhysics in Medicine & Biology, 2009
- Depth of interaction calibration for PET detectors with dual-ended readout by PSAPDsPhysics in Medicine & Biology, 2008
- A Prototype PET Scanner with DOI-Encoding DetectorsJournal of Nuclear Medicine, 2008
- Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodesPhysics in Medicine & Biology, 2006
- Position Sensitive APDs for Small Animal PET ImagingIEEE Transactions on Nuclear Science, 2004
- Position-sensitive avalanche photodiodes for gamma-ray imagingIEEE Transactions on Nuclear Science, 2002
- Initial results from the Sherbrooke avalanche photodiode positron tomographIEEE Transactions on Nuclear Science, 1996